批發(fā)韓國AND KOREA AD-4212C-6000制造廠家中山立訊電氣有限公司直銷中山立訊電氣有限公司銷售韓國DONGYANG F&C 氫氧化鈉自動(dòng)閥
等等,若需了解詳細(xì)的資料,歡迎留言公司網(wǎng)站或來電垂詢??!
DONGYANG F&C 氫氧化鈉自動(dòng)閥
BMO-1000S BMO-1100S BMO-1200S BMO-1300S BMO-1400S BMO-1500S
BMO-2000S BMO-2100S BMO-2200S BMO-2300S BMO-2400S BMO-2500S
BMO-3000S BMO-3100S BMO-3200S BMO-3300S BMO-3400S BMO-3500S
BMO-1010S BMO-1110S BMO-1210S BMO-1310S BMO-1410S BMO-1510S
BMO-2010S BMO-2110S BMO-2210S BMO-2310S BMO-2410S BMO-2510S
BMO-3010S BMO-3110S BMO-3210S BMO-3310S BMO-3410S BMO-3510S
BMO-1020S BMO-1120S BMO-1220S BMO-1320S BMO-1420S BMO-1520S
圖㈡為用通電延時(shí)繼電器代替斷電延時(shí)繼電器的電路。把選擇開關(guān)SA置于1位時(shí),繼電器KA得電吸合并自保持。當(dāng)SA置于2位置時(shí)(或者利用繼電器的一組觸點(diǎn)),通電延時(shí)繼電器KT2獲電,經(jīng)過設(shè)定的延時(shí)時(shí)間,其延時(shí)斷開常閉觸頭斷電。
BMO-2020S BMO-2120S BMO-2220S BMO-2320S BMO-2420S BMO-2520S
BMO-3020S BMO-3120S BMO-3220S BMO-3320S BMO-3420S BMO-3520S
BMO-1001S BMO-1101S BMO-1201S BMO-1301S BMO-1401S BMO-1501S
BMO-2001S BMO-2101S BMO-2201S BMO-2301S BMO-2401S BMO-2501S
BMO-3001S BMO-3101S BMO-3201S BMO-3301S BMO-3401S BMO-3501S
BMO-1011S BMO-1111S BMO-1211S BMO-1311S BMO-1411S BMO-1511S
BMO-2011S BMO-2111S BMO-2211S BMO-2311S BMO-2411S BMO-2511S
BMO-3011S BMO-3110S BMO-3211S BMO-3311S BMO-3411S BMO-3511S
器和空氣斷路器的配合要根據(jù)空氣斷路器的過載系數(shù)和短路保護(hù)電流系數(shù)來決定。器的約定電流應(yīng)小于空氣斷路器的過載電流,器的接通、斷開電流應(yīng)小于斷路器的短路保護(hù)電流,這樣斷路器才能保護(hù)器。實(shí)際中器在一個(gè)電壓等級(jí)下約定電流和額定工作電流比值在1~1.38之間,而斷路器的反時(shí)限過載系數(shù)參數(shù)比較多,不同類型斷路器不一樣,所以兩者間配合很難有一個(gè)標(biāo)準(zhǔn),不能形成配合表,需要實(shí)際核算。
BMO-1021S BMO-1121S BMO-1221S BMO-1321S BMO-1421S BMO-1521S
BMO-2021S BMO-2121S BMO-2221S BMO-2321S BMO-2421S BMO-2521S
BMO-3021S BMO-3121S BMO-3221S BMO-3321S BMO-3421S BMO-3521S
BMO-1002S BMO-1102S BMO-1202S BMO-1302S BMO-1402S BMO-1502S
BMO-2002S BMO-2102S BMO-2202S BMO-2302S BMO-2402S BMO-2502S
BMO-3002S BMO-3102S BMO-3202S BMO-3302S BMO-3402S BMO-3502S
BMO-1012S BMO-1112S BMO-1212S BMO-1312S BMO-1412S BMO-1512S
BMO-2012S BMO-2112S BMO-2212S BMO-2312S BMO-2412S BMO-2512S
上找的,借花獻(xiàn)佛,嘿嘿。上找的,星型接法和三角接法的區(qū)別。在承受相同電壓及相同線徑的繞組線圈中,星型接法比三角型接法每相匝數(shù)少根 3倍(1.732倍),功率也小根 3倍。成品電機(jī)的接法已固定為承受電壓380V,一般不適宜更改?! ‰妷夯ジ衅鞯淖饔镁褪菍⒏唠妷喊凑找欢ū壤P(guān)系,轉(zhuǎn)換成100V或者是等級(jí)更低的標(biāo)準(zhǔn)二次電壓,來為保護(hù)、計(jì)量以及儀表裝置的運(yùn)行提供電能。同時(shí),電壓互感器的另一個(gè)作用是將高電壓與工作人員隔離開來。雖然電壓互感器的工作原理也是按照電磁感應(yīng)原理進(jìn)行的,但是其電磁結(jié)構(gòu)的關(guān)系與電流互感器相比正好是相反狀態(tài)。
BMO-3012S BMO-3110S BMO-3212S BMO-3312S BMO-3412S BMO-3512S
BMO-1022S BMO-1122S BMO-1222S BMO-1322S BMO-1422S BMO-1522S
BMO-2022S BMO-2122S BMO-2222S BMO-2322S BMO-2422S BMO-2522S
BMO-3022S BMO-3122S BMO-3222S BMO-3322S BMO-3422S BMO-3522S
BMO-1003S BMO-1103S BMO-1203S BMO-1303S BMO-1403S BMO-1503S
BMO-2003S BMO-2103S BMO-2203S BMO-2303S BMO-2403S BMO-2503S
BMO-3003S BMO-3103S BMO-3203S BMO-3303S BMO-3403S BMO-3503S
BMO-1013S BMO-1113S BMO-1213S BMO-1313S BMO-1413S BMO-1513S
BMO-2013S BMO-2113S BMO-2213S BMO-2313S BMO-2413S BMO-2513S
BMO-3013S BMO-3110S BMO-3213S BMO-3313S BMO-3413S BMO-3513S
例題1復(fù)雜電路如圖所示,已知V,V,。求:(1)各支路電流;(2)兩點(diǎn)間的電壓;(3)兩電源輸出功率和電阻消耗的功率。解:(1)設(shè)各支路電流為,方向如圖所示。電阻消耗的功率從以上計(jì)算可知,電源輸出的功率,一部分在消耗電阻上,另一部分輸入電源為之充電?! ∮泄β拾聪率接?jì)算:一種功率表對于正弦電路,下式成立:上式中,U、I分別為正弦交流電的有效值,φ為電壓與電流信號(hào)的相位差。在超高頻和微波頻段,有TEM波和非TEM波之分。在TEM波的同軸系統(tǒng)中,電壓和電流雖有確切含意,但測量其絕對值很困難?! ∈褂靡?所有的儀表在第一次使用的時(shí)候,請檢查儀表的參數(shù)周所在配電系統(tǒng)中需要的參數(shù)的一致性。例如,對于AC380V、200A/5A的線路中需要配置AC400V、200A/5A的儀表。用戶也可以根據(jù)實(shí)際需要對儀表重新進(jìn)行編程設(shè)置。
BMO-1023S BMO-1123S BMO-1223S BMO-1323S BMO-1423S BMO-1523S
BMO-2023S BMO-2123S BMO-2223S BMO-2323S BMO-2423S BMO-2523S
BMO-3023S BMO-3123S BMO-3223S BMO-3323S BMO-3423S BMO-3523S
BMO-1004S BMO-1104S BMO-1204S BMO-1304S BMO-1404S BMO-1504S
BMO-2004S BMO-2104S BMO-2204S BMO-2304S BMO-2404S BMO-2504S
BMO-3004S BMO-3104S BMO-3204S BMO-3304S BMO-3404S BMO-3504S
BMO-1014S BMO-1114S BMO-1214S BMO-1314S BMO-1414S BMO-1514S
BMO-2014S BMO-2114S BMO-2214S BMO-2314S BMO-2414S BMO-2514S
BMO-3014S BMO-3110S BMO-3214S BMO-3314S BMO-3414S BMO-3514S
BMO-1024S BMO-1124S BMO-1224S BMO-1324S BMO-1424S BMO-1524S
BMO-2024S BMO-2124S BMO-2224S BMO-2324S BMO-2424S BMO-2524S
BMO-3024S BMO-3124S BMO-3224S BMO-3324S BMO-3424S BMO-3524S
由于分壓電容器上的電壓會(huì)隨負(fù)荷變化,所以,在分壓回路串入電抗器L,可以補(bǔ)償電容器的內(nèi)阻抗,使二次電壓。(3)保護(hù)裝置,由火花間隙P1和P2和阻尼電阻RD組成。1)火花間隙P1和P2,用來限制補(bǔ)償電抗器、電磁式電壓互感器、分壓器的過電壓?! ?5、電壓指數(shù)上升率dv/dt:繼電器的輸出元件能夠承受的不使其導(dǎo)通的電壓上升率。16、工作溫度:繼電器安規(guī)范安裝或不安裝散熱板時(shí),其正常工作的環(huán)境溫度范圍。功率固態(tài)繼電器的特性參數(shù)包括輸入和輸出參數(shù),下面以北京科通繼電器總廠生產(chǎn)的GX-10F繼電器為例,列出輸入、輸出參數(shù),詳見表1,根據(jù)輸入電壓參數(shù)值大小,可確定工作電壓大小。