6kV~35kV 涓綆澹撻妳鑺強閶佽姱浜よ伅(li谩n)鑱氫箼鐑禃绶i浕鍔涢浕绾滐紙YJV闆荤簻锛孻JV22闆荤簻锛孻JLV闆荤簻锛孻JLV22闆荤簻锛� XLPE Insulated Power Cable |
浜よ伅(li谩n)鑱氫箼鐑禃绶i浕鍔涢浕绾滄槸閲囩敤鍖栧(xu茅)鏂规硶鎴栫墿鐞嗘柟娉�,浣胯仛涔欑儻鍒嗗瓙鐢辩窔鍨嬪垎瀛愮祼(ji茅)妲�(g貌u)杞�(zhu菐n)璁�?y艒u)妲款惂S缍�(w菐ng)鐙€绲�(ji茅)妲�(g貌u),鐢辩啽濉戞€х殑鑱氫箼鐑畩鎴愮啽鍥烘€х殑浜よ伅(li谩n)鑱氫箼鐑�,寰炶€屾彁楂樹簡鑱氫箼鐑殑鑰愯€佸寲鎬ц兘銆佹(j墨)姊版€ц兘鍜岃€愮挵(hu谩n)澧冭兘鍔�锛屽苟淇濇寔浜嗗劒(y艒u)鑹殑闆绘埃鎬ц兘銆� 浜よ伅(li谩n)鑱氫箼鐑禃绶i浕鍔涢浕绾滃皫(d菐o)楂旂殑鍏佽ū闀�(zh菐ng)鏈焭ui楂樻韩鐐�90鏀濇皬搴�锛岃純浣庣禃绶i浕绾�銆佽仛姘箼鐑禃绶i浕绾滃拰鑱氫箼鐑禃绶i浕绾滈珮锛屼笖鍏锋湁閲嶉噺杓曘€佺祼(ji茅)妲�(g貌u)绨�(ji菐n)鍠�銆佷娇鐢ㄦ柟渚裤€佽€愬寲瀛�(xu茅)鑵愯潟鍜屾暦瑷�(sh猫)涓嶅彈钀藉樊闄愬埗绛夊劒(y艒u)榛�(di菐n)銆� 26/35KV闆诲姏闆荤簻锛�18/30KV浜よ伅(li谩n)闆荤簻锛�12/20KVYJV闆荤簻锛�8.7/15KVYJV22闆荤簻绶�锛�6/10KV閶佽姱浜よ伅(li谩n)闆荤簻绶氾紝3.6/6KVYJLV鍠姱闆荤簻 涓綆澹撲氦鑱�(li谩n)闆荤簻鐢�(ch菐n)鍝佹(bi膩o)婧�(zh菙n) Standard 鏈敘(ch菐n)鍝佹寜GB12706銆婇瀹氶浕澹�35V鍙婁互涓嬮妳鑺�銆侀媮鑺鏂欑禃绶i浕鍔涢浕绾溿€嬫(bi膩o)婧�(zh菙n)鐢熺敘(ch菐n)锛屽悓鏅�(sh铆)閭勫彲鏍规摎(j霉)鐢ㄦ埗闇€瑕佹寜鍦�(gu贸)闅涢浕宸ュ鍝℃渻(hu矛)鎺ㄨ枽妯�(bi膩o)婧�(zh菙n)IEC銆佽嫳鍦�(gu贸)妯�(bi膩o)婧�(zh菙n)銆佸痉鍦�(gu贸)妯�(bi膩o)婧�(zh菙n)鍙婄編鍦�(gu贸)妯�(bi膩o)婧�(zh菙n)鐢熺敘(ch菐n)銆� The product is manufactured according to the standard of銆奊B12706 or IEC銆丅S銆丏IN and ICEA upon request. 閬╃敤鑼冨湇 Applications 鏈敘(ch菐n)鍝侀仼鐢ㄤ簬宸ラ牷椤嶅畾闆诲3.6/6kv锝�26/35kv杓搁厤闆荤窔璺綔閰嶉€侀浕鑳藉瓙鐢ㄣ€� The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv锝�26/35kv. 浣跨敤鐗规€� Operating characteristics 路 宸ラ牷椤嶅畾闆诲U0/U鐐�3.6/6kv锝�26/35kv銆� Rated power-frepuency voltage U0/U: 3.6/6kv锝�26/35kv. 路 闆荤簻灏�(d菐o)楂旂殑zui楂樺厑瑷卞伐浣滄韩搴︼細90鈩�銆� Max.admissible operating temperature of the conductor:90鈩�. 路 鐭矾鏅�(sh铆)锛坺ui闀�(zh菐ng)鏅�(sh铆)闁撲笉瓒呴亷5s锛夐浕绾滃皫(d菐o)楂旂殑zui楂樻韩搴︿笉瓒呴亷2500C銆� Max. short-circurt temperature of conductor shall not exceed 2500C. 锛�5s maximum duration锛� 路 闆荤簻鏁疯ō(sh猫)鏅�(sh铆)鐠�(hu谩n)澧冩韩搴︽噳(y墨ng)涓嶄綆浜�00C銆� The ambient temperature under installation should not below 00C. 路 闆荤簻褰庢洸鍗婂緫锛氫笁鑺浕绾滀笉灏忎簬闆荤簻澶栧緫15鍊�锛涘柈鑺浕绾滀笉灏忎簬闆荤簻澶栧緫20鍊�銆� The bending radius of a single-core cable should not less than 20 times of the cable diameter. The bending radius of a single-core cable should not less than 15 times of the cable diameter. 闆荤簻椤嶅畾闆诲鐨勯伕鎿� Voltage designation 路 闆荤簻鐨勯瀹氶浕澹撴噳(y墨ng)閬╁悎浜庨浕绾滅郴绲�(t菕ng)鐨勯亱(y霉n)琛岀媭娉�锛岀敤U0/U锛圲m锛塳v琛ㄧず銆� U0锛嶉浕绾滆ō(sh猫)瑷�(j矛)鐢ㄧ殑灏�(d菐o)楂斿皪(du矛)鍦版垨閲戝爆灞忚斀涔嬮枔鐨勯瀹氬伐闋婚浕澹�锛� U锛嶉浕绾滆ō(sh猫)瑷�(j矛)鐢ㄧ殑灏�(d菐o)楂旈枔鐨勯瀹氬伐闋婚浕澹�锛� Um锛嶈ō(sh猫)鍌欏彲鎵垮彈鐨勨€渮ui楂樼郴绲�(t菕ng)闆诲鈥濈殑zui澶у€笺€� The rated voltage of the cable for a given applixation shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the b of U0/U锛圲m锛塳v Where: U0锛峊he rated power-frequency voltage between conductors and earth bllic screen ,for which the cable designed; U 锛� The rated power-frequency voltage between conductos, for which the cable designed; Um锛� The maximum value of the鈥渉ighest system voltage鈥漟or which the equipment may beused. |