汾西縣批發(fā)韓國(guó)Autovalve閥門(mén)DR702-S-P-300-NP2-V-H2中山立訊電氣有限公司直銷(xiāo)中山立訊電氣有限公司銷(xiāo)售韓國(guó)DONGYANG F&C 氫氧化鈉自動(dòng)閥
等等,若需了解詳細(xì)的資料,歡迎留言公司網(wǎng)站或來(lái)電垂詢?。?
DONGYANG F&C 氫氧化鈉自動(dòng)閥
BCS-1000S BCS-1100S BCS-1200S BCS-1300S BCS-1400S BCS-1500S
BCS-2000S BCS-2100S BCS-2200S BCS-2300S BCS-2400S BCS-2500S
BCS-3000S BCS-3100S BCS-3200S BCS-3300S BCS-3400S BCS-3500S
BCS-1010S BCS-1110S BCS-1210S BCS-1310S BCS-1410S BCS-1510S
BCS-2010S BCS-2110S BCS-2210S BCS-2310S BCS-2410S BCS-2510S
BCS-3010S BCS-3110S BCS-3210S BCS-3310S BCS-3410S BCS-3510S
BCS-1020S BCS-1120S BCS-1220S BCS-1320S BCS-1420S BCS-1520S
BCS-2020S BCS-2120S BCS-2220S BCS-2320S BCS-2420S BCS-2520S
BCS-3020S BCS-3120S BCS-3220S BCS-3320S BCS-3420S BCS-3520S
BCS-1001S BCS-1101S BCS-1201S BCS-1301S BCS-1401S BCS-1501S
一旦輸出短路或嚴(yán)重過(guò)載時(shí)間超出幾百毫秒將導(dǎo)致二極管(通常為肖特基二極管)過(guò)熱損壞;其二,當(dāng)由于某種原因,比如人為關(guān)閉,使開(kāi)關(guān)振蕩電路停止工作,負(fù)載端仍然有電壓存在,只是比輸入端低一個(gè)二極管的管壓降而已,這時(shí)輸出仍會(huì)消耗能量。除此之外,如果該殘存電壓低于負(fù)載穩(wěn)態(tài)工作電壓范圍,將使電路處于不確定狀態(tài)。對(duì)于輸出電流相對(duì)較小的應(yīng)用場(chǎng)合(小于5A),利用單片電流模式控制器和高端電流取樣技術(shù),上述兩個(gè)問(wèn)題都可以很好地解決。在這些電路中,二極管被一同步整流開(kāi)關(guān)三極管取代,因此通過(guò)關(guān)閉內(nèi)部開(kāi)關(guān)三極管就可把輸入輸出通路截?cái)?,這樣一來(lái),負(fù)載端對(duì)輸入端來(lái)說(shuō)就呈高阻狀態(tài),而這正是所希望的結(jié)果。在正常工作狀態(tài),電路內(nèi)部的高端取樣電阻對(duì)負(fù)載電流周期性地進(jìn)行采樣。因?yàn)锽G1集電極與BG2基極相連,IC1又是BG2的基極電流Ib2。BG2又把比Ib2(Ib1)放大了β2的集電極電流IC2送回BG1的基極放大。如此循環(huán)放大,直到BGBG2完全導(dǎo)通。實(shí)際這一過(guò)程是“一觸即發(fā)”的過(guò)程,對(duì)可控硅來(lái)說(shuō),觸發(fā)信號(hào)加入控制極,可控硅立即導(dǎo)通。導(dǎo)通的時(shí)間主要決定于可控硅的性能??煽毓枰唤?jīng)觸發(fā)導(dǎo)通后,由于循環(huán)反饋的原因,流入BG1基極的電流已不只是初始的Ib1,而是經(jīng)過(guò)BGBG2放大后的電流(β1*β2*Ib1)這一電流遠(yuǎn)大于Ib1,足以保持BG1的持續(xù)導(dǎo)通。此時(shí)觸發(fā)信號(hào)即使消失,可控硅仍保持導(dǎo)通狀態(tài)只有斷開(kāi)電源Ea或降低Ea,使BGBG2中的集電極電流小于維持導(dǎo)通的值時(shí)。無(wú)需進(jìn)行拆換。耐大電流:自復(fù)絲有極好的耐大電流能力,有的規(guī)格可承受100A電流沖擊。應(yīng)用:PPTC的應(yīng)用范圍很廣,可以用在各種電子產(chǎn)品、通訊產(chǎn)品、電源供應(yīng)器等。相關(guān)說(shuō)明編輯1.正常工作電流在25℃條件下運(yùn)行,絲的電流額定值通常要減少25%以避免有害熔斷。大多數(shù)傳統(tǒng)的絲其采用的材料具有較低的熔化溫度。因此,該種絲對(duì)環(huán)境溫度的變化比較敏感。例如一個(gè)電流額定值為10A的絲通常不推薦在25℃環(huán)境溫度下在大于7.5A的電流下運(yùn)行。汽車(chē)絲汽車(chē)絲2.電壓額定值絲的電壓額定值必須等于或大于有效的電路電壓。一般標(biāo)準(zhǔn)電壓額定值系列為32V、125V、250V、600V。3.電阻絲的電阻在整個(gè)電路中并不重要。由于安培數(shù)小于1的絲電阻只有幾個(gè)歐姆。
BCS-2001S BCS-2101S BCS-2201S BCS-2301S BCS-2401S BCS-2501S
BCS-3001S BCS-3101S BCS-3201S BCS-3301S BCS-3401S BCS-3501S
BCS-1011S BCS-1111S BCS-1211S BCS-1311S BCS-1411S BCS-1511S
BCS-2011S BCS-2111S BCS-2211S BCS-2311S BCS-2411S BCS-2511S
BCS-3011S BCS-3110S BCS-3211S BCS-3311S BCS-3411S BCS-3511S
BCS-1021S BCS-1121S BCS-1221S BCS-1321S BCS-1421S BCS-1521S
BCS-2021S BCS-2121S BCS-2221S BCS-2321S BCS-2421S BCS-2521S
BCS-3021S BCS-3121S BCS-3221S BCS-3321S BCS-3421S BCS-3521S
可以單相使用,也可以用兩臺(tái)接成V-V形作三相使用。實(shí)驗(yàn)室用的電壓互感器往往是原邊多抽頭的,以適應(yīng)測(cè)量不同電壓的需要。供保護(hù)接地用電壓互感器還帶有一個(gè)第三線圈,稱三線圈電壓互感器。三相的第三線圈接成開(kāi)口三角形,開(kāi)口三角形的兩引出端與接地保護(hù)繼電器的電壓線圈聯(lián)接。正常運(yùn)行時(shí),電力系統(tǒng)的三相電壓對(duì)稱,第三線圈上的三相感應(yīng)電動(dòng)勢(shì)之和為零。一旦發(fā)生單相接地時(shí),中性點(diǎn)出現(xiàn)位移,開(kāi)口三角的端子間就會(huì)出現(xiàn)零序電壓使繼電器動(dòng)作,從而對(duì)電力系統(tǒng)起保護(hù)作用。線圈出現(xiàn)零序電壓則相應(yīng)的鐵心中就會(huì)出現(xiàn)零序磁通。為此,這種三相電壓互感器采用旁軛式鐵心(10KV及以下時(shí))或采用三臺(tái)單相電壓互感器。對(duì)于這種互感器,第三線圈的準(zhǔn)確度要求不高。
BCS-1002S BCS-1102S BCS-1202S BCS-1302S BCS-1402S BCS-1502S
BCS-2002S BCS-2102S BCS-2202S BCS-2302S BCS-2402S BCS-2502S
BCS-3002S BCS-3102S BCS-3202S BCS-3302S BCS-3402S BCS-3502S
BCS-1012S BCS-1112S BCS-1212S BCS-1312S BCS-1412S BCS-1512S
BCS-2012S BCS-2112S BCS-2212S BCS-2312S BCS-2412S BCS-2512S
BCS-3012S BCS-3110S BCS-3212S BCS-3312S BCS-3412S BCS-3512S
BCS-1022S BCS-1122S BCS-1222S BCS-1322S BCS-1422S BCS-1522S
BCS-2022S BCS-2122S BCS-2222S BCS-2322S BCS-2422S BCS-2522S
BCS-3022S BCS-3122S BCS-3222S BCS-3322S BCS-3422S BCS-3522S
BCS-1003S BCS-1103S BCS-1203S BCS-1303S BCS-1403S BCS-1503S
BCS-2003S BCS-2103S BCS-2203S BCS-2303S BCS-2403S BCS-2503S
BCS-3003S BCS-3103S BCS-3203S BCS-3303S BCS-3403S BCS-3503S
3.在復(fù)位電路中,S33和S34之間需要接入相應(yīng)的復(fù)位條件。與此同時(shí),Y1和Y2之間的條件也是復(fù)位電路的一部分,兩者條件必須同時(shí)成立.電流互感器[1]是依據(jù)電磁感應(yīng)原理將一次側(cè)大電流轉(zhuǎn)換成二次側(cè)小電流來(lái)測(cè)量的儀器。電流互感器是由閉合的鐵心和繞組組成。它的一次側(cè)繞組匝數(shù)很少,串在需要測(cè)量的電流的線路中。因此它經(jīng)常有線路的全部電流流過(guò),二次側(cè)繞組匝數(shù)比較多,串接在測(cè)量?jī)x表和保護(hù)回路中,電流互感器在工作時(shí),它的二次側(cè)回路始終是閉合的,因此測(cè)量?jī)x表和保護(hù)回路串聯(lián)線圈的阻抗很小,電流互感器的工作狀態(tài)接近短路。電流互感器是把一次側(cè)大電流轉(zhuǎn)換成二次側(cè)小電流來(lái)測(cè)量,二次側(cè)不可開(kāi)路。詞條介紹了其工作原理、參數(shù)說(shuō)明、分類(lèi)、使用介紹等。
BCS-1013S BCS-1113S BCS-1213S BCS-1313S BCS-1413S BCS-1513S
BCS-2013S BCS-2113S BCS-2213S BCS-2313S BCS-2413S BCS-2513S
BCS-3013S BCS-3110S BCS-3213S BCS-3313S BCS-3413S BCS-3513S
BCS-1023S BCS-1123S BCS-1223S BCS-1323S BCS-1423S BCS-1523S
例如個(gè)人電腦,而開(kāi)關(guān)電源就進(jìn)行兩者之間電壓及電流的轉(zhuǎn)換。中文名開(kāi)關(guān)電源外文名SwitchingModePowerSupply(縮寫(xiě):SMPS)性質(zhì)利用現(xiàn)代電力電子技術(shù)方法脈沖寬度調(diào)制特點(diǎn)小型、輕量和高效率目錄1簡(jiǎn)介2主要用途3主要類(lèi)型4基本組成5主要分類(lèi)6發(fā)展方向7工作原理8工作條件9主要特點(diǎn)10工作模式簡(jiǎn)介編輯開(kāi)關(guān)模式電源(SwitchModePowerSupply,簡(jiǎn)稱SMPS),又稱交換式電源、開(kāi)關(guān)變換器,是一種高頻化電能轉(zhuǎn)換裝置,是電源供應(yīng)器的一種。其功能是將一個(gè)位準(zhǔn)的電壓,透過(guò)不同形式的架構(gòu)轉(zhuǎn)換為用戶端所需求的電壓或電流。開(kāi)關(guān)電源的輸入多半是交流電源(例如市電)或是直流電源,而輸出多半是需要直流電源的設(shè)備。
BCS-2023S BCS-2123S BCS-2223S BCS-2323S BCS-2423S BCS-2523S
BCS-3023S BCS-3123S BCS-3223S BCS-3323S BCS-3423S BCS-3523S
BCS-1004S BCS-1104S BCS-1204S BCS-1304S BCS-1404S BCS-1504S
BCS-2004S BCS-2104S BCS-2204S BCS-2304S BCS-2404S BCS-2504S
BCS-3004S BCS-3104S BCS-3204S BCS-3304S BCS-3404S BCS-3504S
BCS-1014S BCS-1114S BCS-1214S BCS-1314S BCS-1414S BCS-1514S
BCS-2014S BCS-2114S BCS-2214S BCS-2314S BCS-2414S BCS-2514S
BCS-3014S BCS-3110S BCS-3214S BCS-3314S BCS-3414S BCS-3514S
BCS-1024S BCS-1124S BCS-1224S BCS-1324S BCS-1424S BCS-1524S
BCS-2024S BCS-2124S BCS-2224S BCS-2324S BCS-2424S BCS-2524S
BCS-3024S BCS-3124S BCS-3224S BCS-3324S BCS-3424S BCS-3524S
1端為其公共端。(自動(dòng)消除導(dǎo)線電阻的影響)?測(cè)量二線制熱電阻信號(hào)時(shí),接13端。(可通過(guò)誤差校正的方法消除導(dǎo)線電阻的影響)?測(cè)量電流信號(hào)時(shí),接23端,其中2端接正,3端接負(fù),?測(cè)量電壓和熱電偶信號(hào)時(shí),接13端,其中1端接正,3端接負(fù)。?繼電器輸出端子為常開(kāi)點(diǎn)。?電源未注明時(shí)一律使用220V電壓。儀表的使用注意事項(xiàng)及保修期z該表可同時(shí)記錄多個(gè)通道,如不全部使用可將剩余通道關(guān)閉z電源工作電壓為:V,不應(yīng)超出z在正常保管與使用情況下,廠方保證儀表使用一年常見(jiàn)錯(cuò)誤分析編輯A:顯示和記錄完全不對(duì)檢查輸入的信號(hào)是否正確接線的位置是否正確,正確接線方法詳見(jiàn)【接線方法】量程代碼是否設(shè)定正確B:有顯示。2)轉(zhuǎn)矩特性、臨界轉(zhuǎn)矩、加速轉(zhuǎn)矩。在同等電機(jī)功率情況下,相對(duì)于高過(guò)載轉(zhuǎn)矩模式,變頻器規(guī)格可以降額選取。3)電磁兼容性。為減少主電源干擾,使用時(shí)可在中間電路或變頻器輸入電路中增加電抗器,或安裝前置隔離變壓器。一般當(dāng)電機(jī)與變頻器距離超過(guò)50m時(shí),應(yīng)在它們中間串入電抗器、濾波器或采用屏蔽防護(hù)電纜。變頻器功率的選用系統(tǒng)效率等于變頻器效率與電動(dòng)機(jī)效率的乘積,只有兩者都處在較高的效率下工作時(shí),則系統(tǒng)效率才較高。從效率角度出發(fā),在選用變頻器功率時(shí),要注意以下幾點(diǎn):1)變頻器功率值與電動(dòng)機(jī)功率值相當(dāng)時(shí)合適,以利變頻器在高的效率值下運(yùn)轉(zhuǎn)。2)在變頻器的功率分級(jí)與電動(dòng)機(jī)功率分級(jí)不相同時(shí),則變頻器的功率要盡可能接近電動(dòng)機(jī)的功率。