人妻综合网,成人影片麻豆国产影片免费观看,中文字幕一区二区人妻电影,欧美性喷潮

產(chǎn)品簡(jiǎn)介
美國(guó)SONOTECH公司SONO950高溫耦合劑
美國(guó)SONOTECH公司SONO950高溫耦合劑
產(chǎn)品價(jià)格:¥詢價(jià)
上架日期:2012-05-08 23:34:29
產(chǎn)地:美國(guó)
發(fā)貨地:深圳
供應(yīng)數(shù)量:不限
最少起訂:1支
瀏覽量:3919
資料下載:暫無(wú)資料下載
其他下載:暫無(wú)相關(guān)下載
詳細(xì)說明

    SONO 950 high temperature ultrasonic couplant

    Sono 950 provides non-toxic coupling for thickness gaging and flaw inspection from 600 (315) to 950 (510). Sono 950 will maintain acoustic coupling beyond 15 seconds to give ample time for obtaining good thickness readings


    Temperature Operating Range

    Thickness Gaging: 600°to950°F(315°to510) Flaw Inspection: 600°to725(315°to385)


    Benefits

    ·Provides an extended open time b for longer inspections.

    ·Non-toxic, non-irritating bula provides inspector safety

    Safety

    ·Non-toxic, non-irritating, biodegradable

    ·Smokes less at elevated temperatures than most high temperature coupling materials

    ·Contains NO perfluorocarbons or fluorinated material, which can cause adverse health effects at high temperatures

    ·Provides operator safety and convenience

    Chemistry

    Total Halogens....................................... <2,500ppm

    Sulfur..................................................<50,000ppm

    Properties

    Viscosity1

    Thin Paste...............................>3,000,000 cps

    (Brookfield LV #5@0.3rpm)

    1 At ambient temperature.

    Auto Ignition temperature………1040oF(560)

    Packaging

    2-oz (50 g) tube

    4-oz (100 g) tube quart (liter) gallon (4-liter)


    Extreme Temperature Guidelines

    ·For best results, allow a few seconds of “melt-time” before taking the temperature reading. Signal attenuation may occur if used at lower than recommended temperature.

    ·A couplant's upper temperature range for short duration thickness gaging is higher than when used for flaw detection.

    ·When testing on vertical or overhead surfaces, a thicker grade of couplant is likely to stay in place, but a thinner grade generally perbs better on flat surfaces.

    ·No Sonotech couplant contains perfluorocarbons; thus "polymer plume fever" is not an operator hazard.

    Flash Po int and Auto Ignition

    Sonotech provides the flash point and auto-ignition temperature for each high temperature product.

    ·The Flash Point of a product is the lowest temperature at which vapors arising from the product will ignite momentarily when exposed to a flame.

    ·Auto Ignition is the temperature at which a substance ignites without other sources of energy.

    The system for flash point determination for high temperature products (>680oF/360oC) utilizes the Cleveland Open Cup test in which vapors are allowed to escape and therefore results in a higher temperature than a closed cup test.


    ·For the flash point of Sono 950 please reference the MSDS on opposing side.

在線詢盤/留言
  • 免責(zé)聲明:以上所展示的信息由企業(yè)自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布企業(yè)負(fù)責(zé),本網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。我們?cè)瓌t 上建議您選擇本網(wǎng)高級(jí)會(huì)員或VIP會(huì)員。