LDP63100-E詳細介紹
LDP63100-E
1/8 DIN Universal Process Panel Meter with built-in USB
DP63100
Built-In USB Programming Port
Modular Output Modules
Universal Process, Voltage, Current, Resistance and Temperature Inputs
Universal AC/DC Power Supply
6/9 Digit Dual Line/ Tri-Color Display with 18 mm (0.71") and 8.9 mm (0.35")
Programmable Units Display
Variable Contrast and Intensity Display
Up to 160 Samples Per Second Conversion Rate
NEMA 4X (IP65) Sealed Front Bezel
產(chǎn)品描述
The DP63100 analog process panel meter offers many features and perbance capabilities to suit a wide range of industrial applications. The DP63100 has a universal b to handle various b signals including DC voltage/current, process, resistance and temperature. The optional plug-in output cards allow the opportunity to configure the meter for present applications, while providing easy upgrades for future needs. The DP63100 employs a dual line, tri-color display with a large 18 mm (0.71"), tri-color 6 digit top display line and a 8.9 mm (0.35"), 9 digit green bottom display line. The meter provides a MAX and MIN reading memory with programmable capture time. The capture time is used to prevent detection of false max or min readings which may occur during start-up or unusual process events.The signal totalizer (integrator) can be used to compute a time-b product. This can be used to provide a readout of totalized flow or calculate service intervals of motors, pumps, etc.
The meter has up to four setpoint outputs, implemented on plug-in option cards. The plug-in cards provide dual FORM-C relays, quad FORM-A, or either quad sinking or quad sourcing open collector logic outputs. The setpoint alarms can be configured to suit a variety of control and alarm requirements.
Communication and bus capabilities are also available as option cards. These include RS232 and RS485. The DP63100 can be programmed to utilize MODBUS? protocol. With MODBUS, the user has access to most configuration beters. Readout values and setpoint alarm values can be controlled through the bus. Additionally, the meter has a feature that allows a remote computer to directly control the outputs of the meter. The DP63100 includes a built-in USB programming port. With a Windows? based program, configuration data can be downloaded to the unit without the need of any additional option cards. A linear DC output signal is available as an optional plug-in card. The card provides either 20 mA or 10V signals. The output can be scaled independent of the b range and can track either the b, totalizer, max or min readings. The meter has been specifically designed for harsh industrial environments. With NEMA 4X (IP65) sealed bezel and extensive testing of noise effects and CE requirements, the meter provides a tough reliable application solution.
SPECIFICATIONS
Display: Negative image LCD
Top Line: 6 digit, 18 mm (0.71"), with tri-color backlight (red, green or orange)
Display Range: -199999 to 999999;
Bottom Line: 9 digit, 8.9 mm (0.35"), with green backlight
Display Range: -199,999,999 to 999,999,999
Power
AC Power: 50 to 250 Vac, 50/60 Hz, 14 VA
DC Power: 21.6 to 250 Vdc, 8 W
Isolation: 2300 Vrms for 1 min to all bs and outputs. KEYPAD: 3 programmable function keys, 5 keys total
A/D Converter: 24 bit resolution
Update Rates: A/D conversion rate; programmable 5 to 160 readings/sec
Thermocouple Inputs
Readout:
Scale: °F or °C
Offset Range: -199,999 to 999,999 display units
Input Impedance: 20 MO
Lead Resistance Effect: 0.03 μV/Ω
Max Continuous Overvoltage: 30V
RTD Inputs
Type: 3 or 4 wire, 2 wire can be compensated for lead wire resistance
Excitation Current: 100 Ω
Range: 136.5 μA ±10%
10 Ω Range: 2.05 mA ±10%
Lead Resistance: 100 Ω
Range: 10 Ω/lead max
10 Ω Range: 3 Ω/lead max
Max Continuous Overload: 30V
Excitation Power: Jumper selectable
Transmitter Power: ±18 Vdc @ 50 mA
Reference Voltage: ±2 Vdc, ±2%
User Inputs
Two Programmable User Inputs Max Continuous Input: 30 Vdc
Isolation to Sensor Input Common: Not isolated
Response Time: 12 msec max
Totalizer
Time Base: Second, minute, hour, or day
Batch: Can accumulate (gate) b display from a user b
Time Accuracy: 0.01% typical
Decimal Point: 0 to 0.0000
Scale Factor: 0.001 to 65.000
Low Signal Cut-Out: -199,999 to 999,999
Total: 6 digits on line 1; 9 digits on line 2
Custom Linearization
Data Point Pairs: Selectable from 2 to 16
Display Range: -199,999 to 999,999
Decimal Point: 0 to 0.0000
Memory: Nonvolatile FRAM memory retains all programmable beters and display values
Environmental Conditions
Operating Temperature Range: 0 to 50°C (32 to 122°F) 0 to 45°C (32 to 113°F) with all three plug-in cards installed
Storage Temperature Range: -40 to 60°C (-40 to 140°F)
Operating and Storage Humidity: 0 to 85% max RH non-condensing
Altitude: Up to 2000 m (6561')
Connections: High compression age-clamp terminal block
Construction: This unit is rated for NEMA 4X (IP65) outdoor use IP20 touch safe. Installation Category II, pollution degree 2. One piece bezel/case. Flame resistant. Synthetic rubber keypad. Panel gasket and mounting clip included.
Dimensions
Case: 44.45 H x 91.44 W x 105 mm D (1.75 x 3.6 x 4.14")
Bezel: 49.53 x 96.52 mm (1.95 x 3.8")
Panel Cutout: 1/8 DIN, 45 x 92 mm (1.77 x 3.62")
Weight: 226.8 g (8 oz)
注: Comes complete with operator’s manual.
Adding option cards to meters can be fitted with up to three optional plug-in cards. However, only one card from each function type can be installed at a time. The function types include Setpoint Alarms, Communications, and Analog Output. The cards can be installed initially or at a later date. Each optional plug-in card is shipped with installation and programming instructions.
產(chǎn)品編號 產(chǎn)品描述
DP63100 1/8 DIN universal process panel meter
Accessories
LDP6-CDS10 Dual setpoint relay output card
LDP6-CDS20 Quad setpoint relay output card
LDP6-CDS30 Quad setpoint sinking open collector output card
LDP6-CDS40 Quad setpoint sourcing open collector output card
LDP6-CDL10 Analog output card
LDP6-CDC10 RS485 serial communications output card with terminal block
LDP6-CDC1C Extended RS485 serial communications output card with dual RJ11 connector
LDP6-CDC20 RS232 serial communications output card with terminal block
LDP6-CDC2C Extended RS232 serial communications output card with 9 pin D connector
產(chǎn)品編號
DP63100
LDP6-CDS10
LDP6-CDS20
LDP6-CDS30
LDP6-CDS40
LDP6-CDL10
LDP6-CDC10
LDP6-CDC1C
LDP6-CDC20
LDP6-CDC2C
LDP63100-E
LDP63100-E 相關(guān)產(chǎn)品
LDP63100-E 技術(shù)文章