本特利傳感器177230-01-01-CN
177230振動(dòng)探頭的特點(diǎn)包括:
易于實(shí)施和使用
- 與PLC和控制系統(tǒng)(如DCS和SCADA)的接口
- 通過(guò)類(lèi)似于連接其他PLC或控制系統(tǒng)輸入的熟悉界面,為作和維護(hù)提供快速學(xué)習(xí)曲線(xiàn)
- 不需要現(xiàn)場(chǎng)配置或調(diào)整
- 完整系統(tǒng)需要額外的零件
- 包括為客戶(hù)提供的技術(shù)支持
監(jiān)視他們的設(shè)備
- 包括自檢
- 包含受保護(hù)的界面
- 支持各種接口電纜
數(shù)據(jù)質(zhì)量
- 提供準(zhǔn)確和可重復(fù)的數(shù)據(jù)
- 使用簡(jiǎn)單的數(shù)據(jù)格式
- 提供原始振動(dòng)信號(hào)進(jìn)行驗(yàn)證和分析
符合EHS標(biāo)準(zhǔn)
- 實(shí)現(xiàn)安全和符合人體工程學(xué)的設(shè)計(jì)
- 支持進(jìn)入危險(xiǎn)區(qū)域
強(qiáng)大的CM設(shè)計(jì)可靠性
實(shí)現(xiàn)工業(yè)標(biāo)準(zhǔn)的4至20mA環(huán)路供電變送器
本特利振動(dòng)探頭是一種簡(jiǎn)單的環(huán)路供電設(shè)備,易于安裝和維護(hù)可降低培訓(xùn)和服務(wù)成本。當(dāng)集成到整個(gè)工廠(chǎng)資產(chǎn)狀況監(jiān)測(cè)解決方案的PLC或控制系統(tǒng)中時(shí),傳感器將幫助您更好地管理停機(jī)時(shí)間,優(yōu)化維護(hù)計(jì)劃并避免機(jī)器資產(chǎn)出現(xiàn)無(wú)法預(yù)料的災(zāi)難性故障。
177230-01-01-CN本特利振動(dòng)探頭
螺柱和適配器:
89139-01 M-M-28 UNF至-24 UNF標(biāo)準(zhǔn)螺栓
128038-01 M-M-28 UNF至-24六角板螺栓(1-“X 0.25”)
146396-01 F-M-18 NPT至-28適配器
146394-01 F-M-28 UNF至-18 NPT適配器
37439-01 F-M-28 UNF至-28 UNF安裝底座
164373 M-M-28 UNF至-28 UNF標(biāo)準(zhǔn)螺栓,帶黃銅
135826-01 M-M-28 UNF到M10 X 1.0標(biāo)準(zhǔn)螺栓
177230地震變送器結(jié)合了可靠的基本保護(hù)解決方案
在GE產(chǎn)品的支持和服務(wù)下。該傳感器是一種簡(jiǎn)單的環(huán)路供電設(shè)備,易于安裝和維護(hù)可降低培訓(xùn)和服務(wù)成本。當(dāng)集成到整個(gè)工廠(chǎng)資產(chǎn)狀況監(jiān)測(cè)解決方案的PLC或控制系統(tǒng)中時(shí),傳感器將幫助您更好地管理停機(jī)時(shí)間,優(yōu)化維護(hù)計(jì)劃并避免機(jī)器資產(chǎn)出現(xiàn)無(wú)法預(yù)料的災(zāi)難性故障。
Bently Nevada* Asset Condition Monitoring
Debion:
The 177230 Seismic Transmitter combines a reliable basic protection solution
with the support and service of GE products. The transducer is a simple, looppowered device whose ease of installation and maintenance may reduce
training and service costs. When integrated into the PLC or controls system of an
overall plant asset condition monitoring solution, the transducer will help you
better manage downtime, optimize maintenance planning, and avoid
unforeseen catastrophic failures of machinery assets.
Features of the 177230 Seismic Transducer include:
· Ease of implementation and use
- Interfaces with PLCs and control systems (like DCS and
SCADA)
- Provides a quick learning curve for operations and
maintenance –through a familiar interface similar to that
for connecting other PLC or control system bs
- Requires no field configuration or adjustments
- Needs few additional parts for a complete system
- Includes technical support for customers on how to
monitor their equipment
- Includes self-test
- Incorporates protected interface
- Supports a variety of interface cables
· Data Quality
- Provides accurate and repeatable data
- Uses simple data bat
- Provides raw vibration signal for verification and analysis
· EHS Compliant
- Implements safe and ergonomic design
- Supports access to hazardous areas
· Incorporates robust CM design for reliability
· Implements Industry standard 4 to 20mA loop-powered transmitter